About this trial
The endotracheal tube is one of the medical devices most associated with pressure injuries related to medical devices. This study aims to evaluate the effectiveness of applying a silicone foam dressing over the endotracheal tube and repositioning the endotracheal tube in preventing endotracheal tube-related pressure injuries in patients receiving mechanical ventilation support.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Aged 18 years or older
Patients admitted to the General Intensive Care Unit and receiving mechanical ventilation support
Absence of pressure injuries, other lesions, or anomalies on the inner and outer surfaces of the lips and at the oral commissures prior to intubation
Absence of congenital anomalies that could interfere with the assessment of pressure injuries on the inner and outer surfaces of the lips and at the oral commissures
Disqualifiers
Receiving mechanical ventilation support initiated prior to admission to the intensive care unit
Undergoing nasotracheal intubation
History of any intraoral surgical procedure
Presence of a contraindication to repositioning of the endotracheal tube
Trial design
Parallel
Treatments tested in this trial
Use of silicone foam dressing and repositioning every 8 hours
Other interventionPatients assigned to this group will receive a silicone foam dressing applied over the endotracheal tube, with repositioning performed every 8 hours. As the silicone foam wound dressing, AQUACEL™ Foam, a sterile, waterproof dressing consisting of a polyurethane outer film layer and a multilayer absorbent pad with silicone adhesive borders, will be used.
Repositioning every 8 hours
Other interventionIn patients assigned to this group, the initial repositioning following intubation and the first assessment of the lips, oral cavity, and perioral skin and mucosa will be performed 8 hours after intubation. If the endotracheal tube (ETT) is positioned at the right or left corner of the mouth, it will be repositioned to the midline; if it is positioned at the midline, it will be repositioned to either the right or left corner of the mouth. Following the initial repositioning, subsequent repositioning procedures will be performed every 8 hours.
Treatment groups
Trial outcomes
Primary outcomes
Assessment of whether a ETT related oral mucosa pressure injury develop
Endotracheal Tube-Related Pressure Injury Assessment Form