The primary objective of this study is to establish the safety and effectiveness of the WATCHMAN Elite Left Atrial Appendage Closure (LAAC) Device for subjects with non-valvular atrial fibrillation who are eligible for anticoagulation therapy to reduce the risk of stroke.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
The subject is of legal age to participate in the study per the laws of their respective geography.
The subject has documented non-valvular atrial fibrillation (i.e., atrial fibrillation in the absence of moderate or greater mitral stenosis or a mechanical heart valve).
The subject has an appropriate rationale to seek a non-pharmacologic alternative to anticoagulation therapy, taking into account the safety and effectiveness of the device compared to anticoagulation therapy.
The subject is deemed to be suitable for the defined protocol pharmacologic regimen of anticoagulation and antiplatelet therapy following WATCHMAN Elite Device implant.
Disqualifiers
The subject is of childbearing potential and is, or plans to become, pregnant during the time of the study (method of assessment upon study physician's discretion).
The subject has a documented life expectancy of less than 2 years.
The subject is currently enrolled, or plans to enroll, in another investigational study or registry that would directly interfere with the current study, except when the subject is participating in a mandatory governmental registry, or a purely observational registry with no associated treatments. Each instance must be brought to the attention of the sponsor to determine eligibility, regardless of type of co-enrollment being proposed.
The subject has a known contraindication to percutaneous catheterization procedure or is contraindicated for transesophageal echocardiography (TEE) or cardiac computed tomography (CT).
Trial design
Single group
Treatments tested in this trial
WATCHMAN Elite LAAC Device
DeviceWATCHMAN Elite LAAC Device Implantation
Treatment groups
Trial outcomes
Primary outcomes
The primary effectiveness endpoint is the rate of effective LAA closure.
The rate of effective LAA closure defined as peri-device flow ≤ 5mm as demonstrated by TEE at the 45-day visit
The primary safety endpoint is the occurrence of pre-specified events between the time of implant and 7 days following the procedure or by hospital discharge, whichever is later.
Occurrence of one of the following events between the time of implant and 7 days following the procedure or by hospital discharge, whichever is later * All-cause death * Ischemic stroke * Systemic embolism * Device or procedure related events requiring open cardiac surgery or major endovascular intervention such as pseudoaneurysm repair, AV fistula repair, or other major endovascular repair. Note: Percutaneous catheter drainage of pericardial effusions, snaring of an embolized device, thrombin injection to treat femoral pseudoaneurysm and minor nonsurgical treatments of access site complications are excluded from this endpoint
Sponsors and contacts
Click on the lead sponsor to view all of their trials.