Using Artificial Intelligence to Screen for Hip Dysplasia

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age4-20
SponsorMurdoch Childrens Research Institute

About this trial

The goal of this clinical trial is to learn if an ultrasound scan using artificial intelligence can accurately screen for hip dysplasia. Researchers will compare the artificial intelligence ultrasound results to the standard ultrasound measures to see if the artificial intelligence ultrasound scan can accurately screen for hip dysplasia.

It will also seek to understand how parents feel about their children undergoing this scan.

Participants will:

* Have an additional ultrasound performed on their child at their scheduled outpatient's appointment for hip dysplasia * Complete a short questionnaire about the experience of having the measurement performed on their child

Eligibility criteria

This trial accepts healthy volunteers

Qualifiers

Enrolled in the VicHip study

Is 4-20 weeks of age at enrolment

Is attending The Royal Children's Hospital for the purpose of the potential diagnosis of DDH

Has a diagnostic (standard) hip ultrasound on the day of their out-patient appointment

Disqualifiers

None

Trial design

Design model

Single group

Treatments tested in this trial

  • Artificial intelligence augmented ultrasound

    Device

    The hip ultrasound is performed using a handheld device (Exo Iris) that uses a pocket-sized ultrasound probe and is run through an application on an IoS (Apple mobile) operation system. . A real-time algorithm detects and records the anatomical landmarks. When there are enough images for analysis the operator is notified that the scan is complete.

Treatment groups

240 Participants
are divided into 1 treatment group
Group A: All active participantsOther 1 intervention

Trial outcomes

Primary outcomes

1

Artificial Intelligence augmented ultrasound screening test capability: Sensitivity

Artificial intelligence (AI) augmented ultrasound results will be compared to standard ultrasound imaging to calculate sensitivity (\[number of true positive cases detected/(number of true positive cases detected + number of false negative cases detected)\] X 100). Groups will be defined as follows: * True positive cases: Flagged for follow-up after the AI assessment of ultrasound sweeps from the portable probe and have a diagnosis of DDH from traditional ultrasound reports. * False positive cases: Flagged for follow-up after the AI assessment of the ultrasound sweeps and do not have a diagnosis of DDH from the traditional ultrasound reports * False negative cases: Return a "normal hips" assessment after the AI assessment of the ultrasound probe and have a diagnosis of DDH from traditional ultrasound reports * True negative cases: Return a "normal hips" assessment after the AI assessment of the ultrasound probe and do not have a diagnosis of DDH from traditional ultrasound reports

Time frame
1 day, both ultrasound scans will be performed on the same day
2

Artificial Intelligence augmented ultrasound screening test capability: Specificity

Artificial intelligence (AI) augmented ultrasound results will be compared to standard ultrasound imaging to calculate specificity (\[number of true negative cases detected/(number of false positive cases detected + number of true negatives cases detected\] X 100). Groups will be defined as follows: * True positive cases: Flagged for follow-up after the AI assessment of ultrasound sweeps from the portable probe and have a diagnosis of DDH from traditional ultrasound reports. * False positive cases: Flagged for follow-up after the AI assessment of the ultrasound sweeps and do not have a diagnosis of DDH from the traditional ultrasound reports * False negative cases: Return a "normal hips" assessment after the AI assessment of the ultrasound probe and have a diagnosis of DDH from traditional ultrasound reports * True negative cases: Return a "normal hips" assessment after the AI assessment of the ultrasound probe and do not have a diagnosis of DDH from traditional ultrasound reports

Time frame
1 day, both ultrasound scans will be performed on the same day
3

Artificial Intelligence augmented ultrasound screening test capability: Positive predictive value (PPV)

Artificial intelligence (AI) augmented ultrasound will be compared to standard ultrasound to calculate PPV (\[number of true positive cases detected/(number of true positive cases detected + number of false positive cases predicted) X 100). Groups will be defined as follows: * True positive cases: Flagged for follow-up after the AI assessment of ultrasound sweeps from the portable probe and have a diagnosis of DDH from traditional ultrasound reports. * False positive cases: Flagged for follow-up after the AI assessment of the ultrasound sweeps and do not have a diagnosis of DDH from the traditional ultrasound reports * False negative cases: Return a "normal hips" assessment after the AI assessment of the ultrasound probe and have a diagnosis of DDH from traditional ultrasound reports * True negative cases: Return a "normal hips" assessment after the AI assessment of the ultrasound probe and do not have a diagnosis of DDH from traditional ultrasound reports

Time frame
1 day, both ultrasound scans will be performed on the same day
4

Artificial Intelligence augmented ultrasound screening test capability: Negative predictive value (NPV)

Artificial intelligence (AI) augmented ultrasound will be compared to standard ultrasound to calculate NPV \[number of true negative cases detected/(number of false negatives detected + number of true negative cases detected) X 100. Groups will be defined as follows: * True positive cases: Flagged for follow-up after the AI assessment of ultrasound sweeps from the portable probe and have a diagnosis of DDH from traditional ultrasound reports. * False positive cases: Flagged for follow-up after the AI assessment of the ultrasound sweeps and do not have a diagnosis of DDH from the traditional ultrasound reports * False negative cases: Return a "normal hips" assessment after the AI assessment of the ultrasound probe and have a diagnosis of DDH from traditional ultrasound reports * True negative cases: Return a "normal hips" assessment after the AI assessment of the ultrasound probe and do not have a diagnosis of DDH from traditional ultrasound reports

Time frame
1 day, both ultrasound scans will be performed on the same day

Secondary outcomes

1

Factors associated with differences in device sensitivity

Sensitivity will be calculated between groups: 1. Degree of dysplasia as defined by the Graf classification 2. Sex 3. Infant age (categorised as 4-7.99 weeks, 8-11.99 weeks, 12-15.99 weeks, 16-20 weeks) 4. Number of scans performed by device operator (less than or greater than 60 scans).

Time frame
1 day, all data will be collected from day of scan
2

Factors associated with differences in device specificity

Analyses will stratified to look at differences in specificity between groups: 1. Degree of dysplasia as defined by the Graf classification 2. Sex 3. Infant age (categorised as 4-7.99 weeks, 8-11.99 weeks, 12-15.99 weeks, 16-20 weeks) 4. Number of scans performed by device operator (less than or greater than 60 scans).

Time frame
1 day, all data will be collected from day of scan
3

Factors associated with differences in device positive predictive value

Positive predictive value will be compared between groups: 1. Degree of dysplasia as defined by the Graf classification 2. Sex 3. Infant age (categorised as 4-7.99 weeks, 8-11.99 weeks, 12-15.99 weeks, 16-20 weeks) 4. Number of scans performed by device operator (less than or greater than 60 scans).

Time frame
1 day, all data will be collected from day of scan
4

Factors associated with differences in device negative predictive value

Negative predictive value will be compared between groups: 1. Degree of dysplasia as defined by the Graf classification 2. Sex 3. Infant age (categorised as 4-7.99 weeks, 8-11.99 weeks, 12-15.99 weeks, 16-20 weeks) 4. Number of scans performed by device operator (less than or greater than 60 scans).

Time frame
1 day, all data will be collected from day of scan

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.