VitaFlow™ II Transcatheter Aortic Valve System Pre-market Trial

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age70+
SponsorShanghai MicroPort CardioFlow Medtech Co., Ltd.

About this trial

This is a pre-market clinical investigation aiming to evaluate the safety and effectiveness of Microport™ CardioFlow VitaFlow™ II Transcatheter Aortic Valve System for the treatment of severe aortic stenosis.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Age≥70 years;

Symptomatic , severe, aortic valve stenosis : peak velocity ≥4.0m/s, or mean transvalvular gradient ≥40mmHg(1 mmHg=0.133kPa), or effective orifice area<0.8cm² (or EOA index<0.5cm²/m²);

NYHA≥II class;

Estimated life-expectancy>12 months after implantation of the prosthetic valve;

Disqualifiers

Acute myocardial infarction (MI) in last 30 days before the treatment;

Aortic root anatomy not suitable for the implantation of the transcatheter aortic valve;

Complicated lesion of the aortic valve (aortic stenosis with severe regurgitation); moderate-severe mitral valve stenosis; severe mitral valve regurgitation; severe tricuspid valve regurgitation;

Previous implantation of heart valve at any position;

Trial design

Design model

Single group

Treatments tested in this trial

  • VitaFlow™ II Transcatheter Aortic Valve System

    Device

    VitaFlow™ II Transcatheter Aortic Valve System contains a valve stent-VitaFlow™ Aortic Valve, a delivery system-VitaFlow™ Delivery System, loading tools, and a guide-wire

Treatment groups

145 Participants
are divided into 1 treatment group
Group A: Single arm clinical investigationExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Rate of all-cause mortality at 12 months post implantation

Rate of all-cause mortality including cardiovascular and non-cardiovascular death

Time frame
12 months post implantation

Secondary outcomes

1

Valve function-mean prosthetic valve gradient

Mean prosthetic valve gradient measured by transthoracic echocardiography (TTE)(in mmHg)

Time frame
at 30 days, 6 months, and 1 year post implantation
2

Valve function- effective orifice area

Effective orifice area measured by transthoracic echocardiography (TTE)(in cm\^2)

Time frame
at 30 days, 6 months, and 1 year post implantation
3

Valve function- degree of prosthetic valve regurgitation

Degree of prosthetic valve regurgitation including paravalvular leak and intravalvular regurgitation measured by transthoracic echocardiography (TTE)

Time frame
at 30 days, 6 months, and 1 year post implantation
4

Rate of safety events according to VARC2

Rate of safety events according to VARC2 including all-cause mortality, myocardial infarction, stroke, bleeding, acute kidney injury, vascular complications, conduction disturbance and arrhythmias, and new permanent pacemaker implantation

Time frame
at 30 days, 6 months, 1 year and annually up to 5 years post implantation

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.