Wavelength Intervention for Nearsighted Kids

ConditionMyopia
Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age7-12
SponsorUniversity of Alabama at Birmingham

About this trial

The goal of this clinical trial is to learn if daily brief periods of specialized soft contact lens wear work to slow the progression of nearsightedness in children. Additionally, the study will learn about the compliance and safety of specialized soft contact lens wear in children. The main questions it aims to answer are:

Does wearing specialized soft contact lenses daily slow myopia progression and axial elongation? What visual/ocular problems do participants have when wearing specialized soft contact lenses? Researchers will compare two soft contact lenses to see if specialized soft contact lens wear works to treat childhood myopia progression.

Participants will

1. Wear either a single type of soft contact lens or two types of soft contact lenses at alternate times daily full time in both eyes for one year. 2. Visit the clinic at 2 weeks, 1 month, 3 months, 6 months, and 12 months for checkups and tests 3. Keep a diary of the lens-wearing times.

Eligibility criteria

This trial accepts healthy volunteers

Qualifiers

Spherical component of refractive error in primary meridian between -0.75 and -5.00 D

Less than 1.00 D of astigmatism or anisometropia

History of soft contact lens wear for at least a week

Best-corrected visual acuity of 20/25 (+0.10 logMAR) or better in each eye

Disqualifiers

Subjects receiving myopia control treatments within the past six months

History of premature (less than 3.3 lb) or preterm birth (earlier than 30 weeks)

Current history of using systemic or ocular medications (including artificial tears) that may affect contact lens wear, tear film health, refractive state, pupillary response or accommodative function

History of ocular or systemic diseases, including those that may affect refractive development

Trial design

Design model

Parallel

Treatments tested in this trial

  • Specialized soft contact lens 1

    Device

    These are daily-wear, daily-replacement lenses. They are identical to specialized soft contact lens 2 in material, comfort, and lens geometry. They differ only in their spectral profile.

  • Specialized soft contact lens 2

    Device

    These are daily-wear, daily-replacement lenses. They are identical to specialized soft contact lens 1 in material, comfort, and lens geometry. They differ only in their spectral profile.

Treatment groups

80 Participants
are divided into 2 treatment groups
Group A: Group AExperimental treatment 1 intervention
Group B: Control groupSham comparator 1 intervention

Trial outcomes

Primary outcomes

1

Change in cycloplegic spherical equivalent refractive error

Cycloplegic autorefraction measurements will be recorded using the WAM 5500 autorefractor in both eyes at baseline and follow-up visits. A set of 10 spherical equivalent measures will be obtained in each eye and later averaged to obtain the eye's final refractive error.

Time frame
Baseline and 12 months
2

Change in axial length

Ocular component dimensions, including axial length, will be recorded using the Haag-Streit LenStar LS900 based on low-coherence interferometry. A set of five measurements in primary gaze in each eye will be averaged to obtain the final dimension of the ocular components.

Time frame
Baseline and 12 months

Secondary outcomes

1

Change in choroidal thickness

Subjects will have cross-sectional chorio-retinal images taken in each eye using a high resolution scan centered on the fovea in the enhanced depth imaging mode. After the scanning is complete, images will be exported in original resolution for offline processing in MATLAB using custom software that will segment layers and automatically measure choroidal thickness at various regions (subfoveal, central, parafoveal, peripheral) as the distance between the retinal pigment epithelium/choroid interface and the choroidoscleral interface.

Time frame
Baseline and 12 months
2

Change in visual acuity

High-contrast distance visual acuity (VA) will be measured at 4 m with ETDRS Charts and near VA will be measured at 40 cm with Near Point Flip Charts. Low-contrast VA will be measured using 10% contrast Bailey Lovey charts. Monocular VA will be recorded in logMAR to the nearest letter on charts standardized to a luminance of 85 cd/m2.

Time frame
Baseline and 12 months
3

Change in accommodative response

A Grand Seiko autorefractor WAM 5500 will be used to measure accommodative response while fixating at 20/100 letters at 40 and 25 cm.

Time frame
Baseline and 12 months

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

University of Alabama at Birmingham

Lead sponsor

National Eye Institute (NEI)

Collaborator